The values of the factor Cb are generally presented as a function of the ratio of modulus of elasticity of soil at the pile base and secant modulus of the surrounding soil (Eb /Es) for various pile-stiffness factor K and various pile length to pile diameter ratios (l/d). These graphs are implemented in the program in a digital format.

Base modulus correction factor for baseload Cb (L/d = 10)

Base modulus correction factor for baseload Cb (L/d = 5)

Literature:

Poulos, H. G. et. Davis, E. H.: Pile Foundations Analysis and Design. New York: John Wiley and Sons, 1980, chapter 5.3.3, pp. 87 - 88 (figure 5.14).